Electrified Applications
ED5000.42
ED5000 Series Pushpad Exit Devices
Latch Pullback - M94 Option with
Norton
®
Powermatic
®
Door Operator
Components
ED5400 x M94 Latch Retraction Exit Device -
Corbin Russwin
781N Power Control Unit - Corbin Russwin
6900 Powermatic - Norton
660 Push Pads - Norton
PTH-2 Power Transfer Hinge - Folger Adam
FAMKA Keyswitch - Corbin Russwin
Operation
Activation and operation of Push
Pads from either side of door will be
controlled by the FAMKA Maintained
Keyswitch. The Push Pads will in turn
activate the 781N Controller for the
Latch Retraction Exit Device. An
internal timer on the 6900 will
coordinate and prevent the door from
being opened before latch retraction
takes place. Standard timers on the 6900
will also provide length of time door is
open and latch being retracted. Door
operator also acts like standard closer
when opened manually.
Rim Exit Device with Delayed Egress
Locking Magnet Having “Y” Option,
Digital Keypads and Electric Strike
Rim Exit Device with Delayed Egress
Locking Magnet Having “Y” Option
on “Exit Only” Door
Components
ED5200 x M52 Exit Device with Cylinder
Dogging - Corbin Russwin
FAIMXO Delay Egress Lock with Ext.
Reset - Folger Adam
310-4 Electric Strike - Folger Adam
PTH-4 Power Transfer Hinge - Folger Adam
FABPS-24-1 Power Supply - Corbin Russwin
FADK-11 Digital Keypads -Corbin Russwin
Surface Door Closer - Corbin Russwin
Operation
Operation of FADK-11 Digital Keypads
are required for authorized ingress or
egress. Unauthorized egress will sound
an alarm and activate the 15- to 30-
second alarm sequence on the FAIMXO
Magnetic Lock. After this time period,
the lock will release and free egress is
possible. When the fire alarm is activated,
power to the magnetic lock will be
interrupted, allowing free egress and
mechanical latching using the 310-4
Electric Strike. Reset and bypass of the
Magnetic Lock is done through the “Y”
switch mounted in the ED5200 exit device.
Components
ED5200 x M52 Exit Device with Cylinder
Dogging - Corbin Russwin
FAIMXO Delay Egress Lock with Ext.
Reset -
Folger Adam
PTH-4 Power Transfer Hinge - Folger Adam
FABPS-24-1 Power Supply - Corbin Russwin
Surface Door Closer - Corbin Russwin
Operation
Operation of the ED5200 x M52 exit
device will sound an alarm and activate
the 15- to 30-second alarm sequence on
the FAIMXO Magnetic Lock. After
this time period, the lock will release
and free egress is possible. When the
fire alarm is activated, power to the
magnetic lock will be interrupted,
allowing free egress and mechanical
latching. Authorized alarm bypass and
reset is done through the “Y” option
keyswitch located in the exit device.
FAMKA
FAIMXO
FABPS-
24-1
FABPS-
24-1
FAIMXO